SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
MICROCRE · RESEARCH SCIENCE

光谱仪 — Infrared thermometry and emissivity

A schematic of the measurement chain, not device footage or data.

Schematic demonstration: scale, speed and colour do not represent instrument measurements.

Translation pending review.

Instrument role

Measurement and analysis

Operating principle

Principle summary

For this task the 光谱仪 family measures as follows: Infrared thermometry and emissivity. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.

Equation

C = 12.1 · d³ / L

Variables and units
  • Symbol

    d

    Item

    Tube diameter

    Unit

    cm

  • Symbol

    L

    Item

    Tube length

    Unit

    cm

Assumptions and limits
  • Conditions are stable and calibrated as defined

  • Inputs are independent without unmodelled bias

  • Interpretation stays within this family and the stated conditions

Research objects

  • Research object: GCr15 bearing steel

  • Research object: H13 hot-work tool steel

  • Research object: DC53 cold-work die steel

Research questions

  • What dominates the error budget for Infrared thermometry and emissivity?

  • Does the conclusion hold for another batch or process?

Applications

  • Infrared thermometry and emissivity: GCr15 bearing steel

  • Infrared thermometry and emissivity: H13 hot-work tool steel

From specimen to result

  1. 01
    Title

    Fix the analyte or property

    Action

    Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

    Input

    Previous output

    Output

    Step 1 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  2. 02
    Title

    Sample and pre-treat

    Action

    Prepare specimens or measurement points for the material and purpose: build calibration and blanks, verify detection limit and drift, avoid contamination during digestion or preparation, and insert quality-control samples in each batch.

    Input

    Previous output

    Output

    Step 2 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  3. 03
    Title

    Build calibration and QC

    Action

    Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

    Input

    Previous output

    Output

    Step 3 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step
  4. 04
    Title

    Measure per method

    Action

    Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

    Input

    Previous output

    Output

    Step 4 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  5. 05
    Title

    Check interference and LOD

    Action

    Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

    Input

    Previous output

    Output

    Step 5 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  6. 06
    Title

    Compute content and report

    Action

    Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

    Input

    Previous output

    Output

    Step 6 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step

Methods and standards

  • compositional and thermal analysis

  • Confirm force, range and threshold against the applicable standard

Standards and applicability

  • ASTM E1004-17

  • ASTM E691-22

  • GB/T 4336-2016

  • GB/T 11170-2008

  • GB/T 14203-2016

Configuration and service checks

  • Calibration and intermediate check records

  • Fixtures, accessories and range confirmation

Limitations

  • Family-level guidance, not a specific model capability

  • Re-confirm method and criteria outside the stated conditions

Search terms

  • AI

  • 材料数据库

  • 材料制备方案

  • 测试流程建议

  • 性能预测

  • 传统仪器升级改造

  • 芯片测试

  • 仪器全自动化

Related instruments, methods and research

Paper links indicate related methods or objects; they do not establish use of this instrument model.

Relation commonly used for this task

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.