SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
MICROCRE · RESEARCH SCIENCE

复合材料断裂韧性与残余应力 — Creep and stress rupture

A schematic of the measurement chain, not device footage or data.

Schematic demonstration: scale, speed and colour do not represent instrument measurements.

Translation pending review.

Instrument role

Measurement and analysis

Operating principle

Principle summary

For this task the 复合材料断裂韧性与残余应力 family measures as follows: Creep and stress rupture. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.

Equation

DOF = λ/(NA²) + e/(M·NA)

Variables and units
  • Symbol

    lam

    Item

    Wavelength

    Unit

    nm

  • Symbol

    NA

    Item

    Numerical aperture

    Unit

    1

  • Symbol

    e

    Item

    Pixel size

    Unit

    µm

  • Symbol

    M

    Item

    Magnification

    Unit

    1

Assumptions and limits
  • Conditions are stable and calibrated as defined

  • Inputs are independent without unmodelled bias

  • Interpretation stays within this family and the stated conditions

Research objects

  • Research object: BK7 optical glass

  • Research object: sapphire window

  • Research object: monocrystalline silicon wafer

Research questions

  • What dominates the error budget for Creep and stress rupture?

  • Does the conclusion hold for another batch or process?

Applications

  • Creep and stress rupture: TA15 titanium alloy

  • Creep and stress rupture: GH4169 nickel-based superalloy

From specimen to result

  1. 01
    Title

    Fix the property, method and standard

    Action

    Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

    Input

    Previous output

    Output

    Step 1 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  2. 02
    Title

    Machine and measure specimens

    Action

    Prepare specimens or measurement points for the material and purpose: machine specimens to the standard, measure actual dimensions, align the grips, preload and then load at the specified rate while recording force, displacement and time.

    Input

    Previous output

    Output

    Step 2 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  3. 03
    Title

    Align grips and mount the extensometer

    Action

    Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

    Input

    Previous output

    Output

    Step 3 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step
  4. 04
    Title

    Load at the specified rate and acquire

    Action

    Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

    Input

    Previous output

    Output

    Step 4 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  5. 05
    Title

    Check failure mode and validity

    Action

    Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

    Input

    Previous output

    Output

    Step 5 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  6. 06
    Title

    Compute properties and report

    Action

    Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

    Input

    Previous output

    Output

    Step 6 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step

Methods and standards

  • mechanical property testing

  • Confirm force, range and threshold against the applicable standard

Standards and applicability

  • GB/T 4161-2007

  • GB/T 6398-2017

  • GB/T 21143-2014

  • ISO 12108:2018

  • ISO 12135:2021

Configuration and service checks

  • Calibration and intermediate check records

  • Fixtures, accessories and range confirmation

Limitations

  • Family-level guidance, not a specific model capability

  • Re-confirm method and criteria outside the stated conditions

Search terms

  • SHPB

  • 霍普金森

  • 高速疲劳

  • 低温力学

  • 多物理场

  • 材料力学试验

  • 试验机

  • 疲劳

  • 冲击

  • 航空航天

Related instruments, methods and research

Relation commonly used for this task

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.