MICROCRE · RESEARCH SCIENCE

Cryogenic tensile and transition behaviour: complete workflow

Translation pending review.

Research track

performance

Research objective

Test plan for "Cryogenic tensile and transition behaviour". Specimens of Cf/SiC ceramic matrix composite are measured under high-temperature oxidation in air at 900 °C following mechanical property testing. The plan fixes sampling, measurement parameters, acceptance basis and record format, and reports roundness and cylindricity with explicit limits of interpretation.

Objective

Obtain a reproducible roundness and cylindricity under high-temperature oxidation in air at 900 °C.

Required inputs

  • Specimen condition and batch

  • Calibration and range confirmation

  • Acceptance basis and record sheet

Workflow steps

  1. 01
    Title

    Fix the property, method and standard

    Action

    Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

    Input

    Output of the previous step and the environment log

    Output

    Step 1 record: roundness and cylindricity

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step
  2. 02
    Title

    Machine and measure specimens

    Action

    Prepare specimens or measurement points for the material and purpose: machine specimens to the standard, measure actual dimensions, align the grips, preload and then load at the specified rate while recording force, displacement and time.

    Input

    Output of the previous step and the environment log

    Output

    Step 2 record: roundness and cylindricity

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step
  3. 03
    Title

    Align grips and mount the extensometer

    Action

    Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

    Input

    Output of the previous step and the environment log

    Output

    Step 3 record: roundness and cylindricity

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step
  4. 04
    Title

    Load at the specified rate and acquire

    Action

    Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

    Input

    Output of the previous step and the environment log

    Output

    Step 4 record: roundness and cylindricity

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step
  5. 05
    Title

    Check failure mode and validity

    Action

    Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

    Input

    Output of the previous step and the environment log

    Output

    Step 5 record: roundness and cylindricity

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step
  6. 06
    Title

    Compute properties and report

    Action

    Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

    Input

    Output of the previous step and the environment log

    Output

    Step 6 record: roundness and cylindricity

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step

Equations and variables

  • Item

    Hollomon 加工硬化指数

    Equation

    n = (ln σ₂ − ln σ₁)/(ln ε₂ − ln ε₁)

    Variables and units

    应力 1、真应变 1、应力 2、真应变 2

    Assumptions and limits

    按定义单位代入;测量条件稳定

    Worked example

    示例值仅用于演示代入过程

Worked example

Input parameters

Assumed inputs for Cf/SiC ceramic matrix composite under high-temperature oxidation in air at 900 °C

Calculation

Substitute step by step and keep significant digits

Result

Produces a teaching value, not an acceptance value

Limitations

Example excludes systematic equipment bias

Deliverables

  • Raw records and processing sheet

  • Result and uncertainty

Errors and risks

  • Measuring before the environment stabilises

  • Treating one batch as process capability evidence

Instrument applicability

Organised around the Mechanical testing family in the catalogue; confirm model capability and accessories.

Required external capabilities

Preparation, loading or analysis equipment outside this catalogue may be required.

Literature scope

Literature links indicate related methods or objects, not use of our instruments.

Instrument roles in the workflow

Language note

V9 结构化生成条目,发布前须由领域工程师复核技术细节。

Search terms

  • 检测方法

  • 标准规范

  • 选型方案

  • 科研流程

  • 模拟实验