电子万能试验机 — Low-temperature impact and fracture appearance
A schematic of the measurement chain, not device footage or data.
Schematic demonstration: scale, speed and colour do not represent instrument measurements.
Translation pending review.
Instrument role
Measurement and analysis
Operating principle
For this task the 电子万能试验机 family measures as follows: Low-temperature impact and fracture appearance. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.
θ″ = θ_rad · 206265
- Symbol
rad
ItemAngle
Unitrad
Conditions are stable and calibrated as defined
Inputs are independent without unmodelled bias
Interpretation stays within this family and the stated conditions
Research objects
Research object: PTFE seal
Research object: silicone rubber O-ring
Research object: fused silica
Research questions
What dominates the error budget for Low-temperature impact and fracture appearance?
Does the conclusion hold for another batch or process?
Applications
Low-temperature impact and fracture appearance: 316L stainless steel weld
Low-temperature impact and fracture appearance: 2205 duplex stainless steel
From specimen to result
- 01Title
Fix the property, method and standard
ActionTurn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.
InputPrevious output
OutputStep 1 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 02Title
Machine and measure specimens
ActionPrepare specimens or measurement points for the material and purpose: machine specimens to the standard, measure actual dimensions, align the grips, preload and then load at the specified rate while recording force, displacement and time.
InputPrevious output
OutputStep 2 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 03Title
Align grips and mount the extensometer
ActionVerify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.
InputPrevious output
OutputStep 3 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
- 04Title
Load at the specified rate and acquire
ActionExecute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.
InputPrevious output
OutputStep 4 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 05Title
Check failure mode and validity
ActionJudge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.
InputPrevious output
OutputStep 5 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 06Title
Compute properties and report
ActionReport method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.
InputPrevious output
OutputStep 6 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
Methods and standards
mechanical property testing
Confirm force, range and threshold against the applicable standard
Standards and applicability
GB/T 10623-2008
GB/T 228.1-2021
GB/T 228.2-2015
GB/T 7314-2017
GB/T 232-2010
Configuration and service checks
Calibration and intermediate check records
Fixtures, accessories and range confirmation
Limitations
Family-level guidance, not a specific model capability
Re-confirm method and criteria outside the stated conditions
Search terms
SHPB
霍普金森
高速疲劳
低温力学
多物理场
材料力学试验
试验机
疲劳
冲击
航空航天
Related instruments, methods and research
Paper links indicate related methods or objects; they do not establish use of this instrument model.
Relation commonly used for this task