Crack length and propagation path: complete workflow
Translation pending review.
Research track
development
Research objective
Test plan for "Crack length and propagation path". Specimens of SiC power device solder layer are measured under ambient laboratory air following microscopic observation and image measurement. The plan fixes sampling, measurement parameters, acceptance basis and record format, and reports flatness and parallelism with explicit limits of interpretation.
Objective
Obtain a reproducible flatness and parallelism under ambient laboratory air.
Required inputs
Specimen condition and batch
Calibration and range confirmation
Acceptance basis and record sheet
Workflow steps
- 01Title
Fix the purpose and magnification
ActionTurn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.
InputOutput of the previous step and the environment log
OutputStep 1 record: flatness and parallelism
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 02Title
Prepare and clean the surface
ActionPrepare specimens or measurement points for the material and purpose: select the objective by magnification and working distance, calibrate the scale and white balance, avoid clipping, and compare quantitatively under identical illumination and thresholds.
InputOutput of the previous step and the environment log
OutputStep 2 record: flatness and parallelism
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 03Title
Calibrate scale and illumination
ActionVerify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.
InputOutput of the previous step and the environment log
OutputStep 3 record: flatness and parallelism
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 04Title
Capture representative images
ActionExecute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.
InputOutput of the previous step and the environment log
OutputStep 4 record: flatness and parallelism
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 05Title
Segment and measure with thresholds
ActionJudge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.
InputOutput of the previous step and the environment log
OutputStep 5 record: flatness and parallelism
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 06Title
Review statistics and report
ActionReport method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.
InputOutput of the previous step and the environment log
OutputStep 6 record: flatness and parallelism
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
Equations and variables
- Item
真空抽气时间
Equationt = (V/S) · ln(P₀/P)
Variables and units腔体容积、有效抽速、初始压力、目标压力
Assumptions and limits按定义单位代入;测量条件稳定
Worked example示例值仅用于演示代入过程
Worked example
Assumed inputs for SiC power device solder layer under ambient laboratory air
Substitute step by step and keep significant digits
Produces a teaching value, not an acceptance value
Example excludes systematic equipment bias
Deliverables
Raw records and processing sheet
Result and uncertainty
Errors and risks
Measuring before the environment stabilises
Treating one batch as process capability evidence
Instrument applicability
Organised around the Microscopy & image analysis family in the catalogue; confirm model capability and accessories.
Required external capabilities
Preparation, loading or analysis equipment outside this catalogue may be required.
Literature scope
Literature links indicate related methods or objects, not use of our instruments.
Instrument roles in the workflow
| Instrument family | Role and applicability | Workflow steps |
|---|---|---|
Performs a measurement or preparation step | Calibrate scale and illumination · Capture representative images | |
Performs a measurement or preparation step | Calibrate scale and illumination · Capture representative images | |
Performs a measurement or preparation step | Calibrate scale and illumination · Capture representative images |
Language note
V9 结构化生成条目,发布前须由领域工程师复核技术细节。