Multiaxial fatigue with phase-shifted loading: complete workflow
Translation pending review.
Research track
performance
Research objective
Test plan for "Multiaxial fatigue with phase-shifted loading". Specimens of PTFE seal are measured under high vacuum 1e-4 Pa following mechanical property testing. The plan fixes sampling, measurement parameters, acceptance basis and record format, and reports impact absorbed energy KV2 with explicit limits of interpretation.
Objective
Obtain a reproducible impact absorbed energy KV2 under high vacuum 1e-4 Pa.
Required inputs
Specimen condition and batch
Calibration and range confirmation
Acceptance basis and record sheet
Workflow steps
- 01Title
Fix the property, method and standard
ActionTurn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.
InputOutput of the previous step and the environment log
OutputStep 1 record: impact absorbed energy KV2
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 02Title
Machine and measure specimens
ActionPrepare specimens or measurement points for the material and purpose: machine specimens to the standard, measure actual dimensions, align the grips, preload and then load at the specified rate while recording force, displacement and time.
InputOutput of the previous step and the environment log
OutputStep 2 record: impact absorbed energy KV2
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 03Title
Align grips and mount the extensometer
ActionVerify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.
InputOutput of the previous step and the environment log
OutputStep 3 record: impact absorbed energy KV2
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 04Title
Load at the specified rate and acquire
ActionExecute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.
InputOutput of the previous step and the environment log
OutputStep 4 record: impact absorbed energy KV2
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 05Title
Check failure mode and validity
ActionJudge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.
InputOutput of the previous step and the environment log
OutputStep 5 record: impact absorbed energy KV2
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 06Title
Compute properties and report
ActionReport method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.
InputOutput of the previous step and the environment log
OutputStep 6 record: impact absorbed energy KV2
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
Equations and variables
- Item
Paris 裂纹扩展速率
Equationda/dN = C (ΔK)^m
Variables and unitsParis 系数、应力强度因子幅、Paris 指数
Assumptions and limits按定义单位代入;测量条件稳定
Worked example示例值仅用于演示代入过程
Worked example
Assumed inputs for PTFE seal under high vacuum 1e-4 Pa
Substitute step by step and keep significant digits
Produces a teaching value, not an acceptance value
Example excludes systematic equipment bias
Deliverables
Raw records and processing sheet
Result and uncertainty
Errors and risks
Measuring before the environment stabilises
Treating one batch as process capability evidence
Instrument applicability
Organised around the Mechanical testing family in the catalogue; confirm model capability and accessories.
Required external capabilities
Preparation, loading or analysis equipment outside this catalogue may be required.
Literature scope
Literature links indicate related methods or objects, not use of our instruments.
Instrument roles in the workflow
| Instrument family | Role and applicability | Workflow steps |
|---|---|---|
Performs a measurement or preparation step | Align grips and mount the extensometer · Load at the specified rate and acquire | |
Performs a measurement or preparation step | Align grips and mount the extensometer · Load at the specified rate and acquire | |
Performs a measurement or preparation step | Align grips and mount the extensometer · Load at the specified rate and acquire |
Language note
V9 结构化生成条目,发布前须由领域工程师复核技术细节。
Search terms
检测方法
标准规范
选型方案
科研流程