SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
MICROCRE · RESEARCH SCIENCE

陶瓷基准平尺 — Straightness calibration of a precision stage

A schematic of the measurement chain, not device footage or data.

Schematic demonstration: scale, speed and colour do not represent instrument measurements.

Translation pending review.

Instrument role

Measurement and analysis

Operating principle

Principle summary

For this task the 陶瓷基准平尺 family measures as follows: Straightness calibration of a precision stage. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.

Equation

θ = TL / (GJ) · 180/π

Variables and units
  • Symbol

    T

    Item

    Torque

    Unit

    N·mm

  • Symbol

    L

    Item

    Length

    Unit

    mm

  • Symbol

    G

    Item

    Shear modulus

    Unit

    MPa

  • Symbol

    J

    Item

    Polar moment

    Unit

    mm⁴

Assumptions and limits
  • Conditions are stable and calibrated as defined

  • Inputs are independent without unmodelled bias

  • Interpretation stays within this family and the stated conditions

Research objects

  • Research object: ZTA zirconia-toughened alumina

  • Research object: Si3N4 silicon nitride ceramic

  • Research object: SiC silicon carbide ceramic

Research questions

  • What dominates the error budget for Straightness calibration of a precision stage?

  • Does the conclusion hold for another batch or process?

Applications

  • Straightness calibration of a precision stage: ZTA zirconia-toughened alumina

  • Straightness calibration of a precision stage: Si3N4 silicon nitride ceramic

From specimen to result

  1. 01
    Title

    Establish the datum and coordinate frame

    Action

    Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

    Input

    Previous output

    Output

    Step 1 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  2. 02
    Title

    Set the mirror and targets

    Action

    Prepare specimens or measurement points for the material and purpose: clean and thermally soak the datum, place the mirror or target along the travel, verify zero and bidirectional repeatability, then step at equal intervals.

    Input

    Previous output

    Output

    Step 2 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  3. 03
    Title

    Verify zero and repeatability

    Action

    Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

    Input

    Previous output

    Output

    Step 3 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step
  4. 04
    Title

    Acquire angle or displacement in steps

    Action

    Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

    Input

    Previous output

    Output

    Step 4 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  5. 05
    Title

    Fit straightness and angular error

    Action

    Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

    Input

    Previous output

    Output

    Step 5 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  6. 06
    Title

    Assess environment and uncertainty

    Action

    Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

    Input

    Previous output

    Output

    Step 6 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step

Methods and standards

  • small-angle and straightness measurement

  • Confirm force, range and threshold against the applicable standard

Standards and applicability

  • JJG 117-2013

Configuration and service checks

  • Calibration and intermediate check records

  • Fixtures, accessories and range confirmation

Limitations

  • Family-level guidance, not a specific model capability

  • Re-confirm method and criteria outside the stated conditions

Search terms

  • 几何计量

  • 无损检测

  • 自准直仪

  • 精密运动控制

  • 芯片测试

Related instruments, methods and research

Paper links indicate related methods or objects; they do not establish use of this instrument model.

Relation commonly used for this task

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕