For this task the 金相制样耗材 family measures as follows: Measuring heat-affected zone width. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.

Equation

Z = (S₀ − S_u)/S₀ · 100 %

Variables and units
  • Symbol

    S0

    Item

    Original area

    Unit

    mm²

  • Symbol

    Su

    Item

    Fracture area

    Unit

    mm²

Assumptions and limits
  • Conditions are stable and calibrated as defined

  • Inputs are independent without unmodelled bias

  • Interpretation stays within this family and the stated conditions

Research objects

  • Research object: 7075 aluminium alloy

  • Research object: 2024 aluminium riveted joint

  • Research object: AZ91D magnesium alloy

Research questions

  • What dominates the error budget for Measuring heat-affected zone width?

  • Does the conclusion hold for another batch or process?

Applications

  • Measuring heat-affected zone width: 7075 aluminium alloy

  • Measuring heat-affected zone width: 2024 aluminium riveted joint

From specimen to result

  1. 01
    Title

    Define the section plane and location

    Action

    Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

    Input

    Previous output

    Output

    Step 1 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  2. 02
    Title

    Select cutting process and cooling

    Action

    Prepare specimens or measurement points for the material and purpose: select the cut-off wheel and cooling by hardness and microstructure, then grind and polish stepwise with cleaning between steps to avoid smearing and relief.

    Input

    Previous output

    Output

    Step 2 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  3. 03
    Title

    Mount and label the specimen

    Action

    Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

    Input

    Previous output

    Output

    Step 3 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step
  4. 04
    Title

    Grind and polish stepwise

    Action

    Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

    Input

    Previous output

    Output

    Step 4 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  5. 05
    Title

    Etch and inspect under the microscope

    Action

    Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

    Input

    Previous output

    Output

    Step 5 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  6. 06
    Title

    Record parameters and artefacts

    Action

    Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

    Input

    Previous output

    Output

    Step 6 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step

Methods and standards

  • sectioning, mounting and polishing workflow

  • Confirm force, range and threshold against the applicable standard

Configuration and service checks

  • Calibration and intermediate check records

  • Fixtures, accessories and range confirmation

Limitations

  • Family-level guidance, not a specific model capability

  • Re-confirm method and criteria outside the stated conditions

Search terms

  • AI

  • 材料数据库

  • 性能预测

  • 仪器全自动化

  • 升级改造

  • 精密运动控制

  • 测试流程建议

  • 采集频率

Related instruments, methods and research

Relation commonly used for this task

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.