清洁度检测分析 — Inclusion rating
A schematic of the measurement chain, not device footage or data.
Schematic demonstration: scale, speed and colour do not represent instrument measurements.
Translation pending review.
Instrument role
Measurement and analysis
Operating principle
For this task the 清洁度检测分析 family measures as follows: Inclusion rating. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.
P_cr = π²EI / (KL)²
- Symbol
E
ItemElastic modulus
UnitMPa
- Symbol
I
ItemSecond moment
Unitmm⁴
- Symbol
K
ItemEffective length factor
Unit1
- Symbol
L
ItemLength
Unitmm
Conditions are stable and calibrated as defined
Inputs are independent without unmodelled bias
Interpretation stays within this family and the stated conditions
Research objects
Research object: carbon-fibre epoxy laminate
Research object: glass-fibre reinforced nylon
Research object: PEEK engineering polymer
Research questions
What dominates the error budget for Inclusion rating?
Does the conclusion hold for another batch or process?
Applications
Inclusion rating: H13 hot-work tool steel
Inclusion rating: DC53 cold-work die steel
From specimen to result
- 01Title
Fix the purpose and magnification
ActionTurn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.
InputPrevious output
OutputStep 1 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 02Title
Prepare and clean the surface
ActionPrepare specimens or measurement points for the material and purpose: select the objective by magnification and working distance, calibrate the scale and white balance, avoid clipping, and compare quantitatively under identical illumination and thresholds.
InputPrevious output
OutputStep 2 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 03Title
Calibrate scale and illumination
ActionVerify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.
InputPrevious output
OutputStep 3 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
- 04Title
Capture representative images
ActionExecute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.
InputPrevious output
OutputStep 4 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 05Title
Segment and measure with thresholds
ActionJudge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.
InputPrevious output
OutputStep 5 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 06Title
Review statistics and report
ActionReport method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.
InputPrevious output
OutputStep 6 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
Methods and standards
microscopic observation and image measurement
Confirm force, range and threshold against the applicable standard
Standards and applicability
GB/T 18876.1-2002
GB/T 18876.2-2006
ISO 14644-1:2015
ISO 14644-2:2015
ASTM E45-18a
Configuration and service checks
Calibration and intermediate check records
Fixtures, accessories and range confirmation
Limitations
Family-level guidance, not a specific model capability
Re-confirm method and criteria outside the stated conditions
Search terms
显微成像
DIC
散斑
离子束
电子束
芯片测试
显微分析
Related instruments, methods and research
Relation commonly used for this task
