自准直仪 — Abbe and cosine error correction
A schematic of the measurement chain, not device footage or data.
Schematic demonstration: scale, speed and colour do not represent instrument measurements.
Translation pending review.
Instrument role
Measurement and analysis
Operating principle
For this task the 自准直仪 family measures as follows: Abbe and cosine error correction. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.
r = ε_width / ε_thickness
- Symbol
ew
ItemWidth strain
Unit%
- Symbol
et
ItemThickness strain
Unit%
Conditions are stable and calibrated as defined
Inputs are independent without unmodelled bias
Interpretation stays within this family and the stated conditions
Research objects
Research object: 2024 aluminium riveted joint
Research object: AZ91D magnesium alloy
Research object: ZTA zirconia-toughened alumina
Research questions
What dominates the error budget for Abbe and cosine error correction?
Does the conclusion hold for another batch or process?
Applications
Abbe and cosine error correction: 2024 aluminium riveted joint
Abbe and cosine error correction: AZ91D magnesium alloy
From specimen to result
- 01Title
Establish the datum and coordinate frame
ActionTurn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.
InputPrevious output
OutputStep 1 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 02Title
Set the mirror and targets
ActionPrepare specimens or measurement points for the material and purpose: clean and thermally soak the datum, place the mirror or target along the travel, verify zero and bidirectional repeatability, then step at equal intervals.
InputPrevious output
OutputStep 2 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 03Title
Verify zero and repeatability
ActionVerify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.
InputPrevious output
OutputStep 3 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
- 04Title
Acquire angle or displacement in steps
ActionExecute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.
InputPrevious output
OutputStep 4 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 05Title
Fit straightness and angular error
ActionJudge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.
InputPrevious output
OutputStep 5 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 06Title
Assess environment and uncertainty
ActionReport method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.
InputPrevious output
OutputStep 6 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
Methods and standards
small-angle and straightness measurement
Confirm force, range and threshold against the applicable standard
Standards and applicability
GB/T 24762-2009
ISO 10110-1:2019
ISO 10110-5:2015
ISO 10110-8:2019
ISO 10110-14:2018
Configuration and service checks
Calibration and intermediate check records
Fixtures, accessories and range confirmation
Limitations
Family-level guidance, not a specific model capability
Re-confirm method and criteria outside the stated conditions
Search terms
自准直仪
几何计量
精密运动控制
光学计量
角度计量
Related instruments, methods and research
Paper links indicate related methods or objects; they do not establish use of this instrument model.
Relation commonly used for this task