Product Description:
HMAS-D5/10/20/30/50 Vickers hardness measurement and analysis system is a new high-tech product of the company's sixth generation photoelectric integration. The machine modelling is novel, has good reliability, operability and intuitive, is to use precision machinery technology, photoelectric technology, image processing technology and new material hardness analysis software Vickers and Knoop hardness test instrument.
Performance Features:
1. The appearance is novel, and the intelligent measurement is further realized through the operation of software
2. It is easier to measure the method by removing the traditional tedious measurement procedure
3. The equipment is equipped with printing function, which can print and save relevant measurement parameters
4. The equipment can be photographed and analyzed and read the material
5. Adjustable measuring light source strength, preset test force retention time, and can switch the Vickers and Knudsen test methods
Scope of use:
Heat treatment, carbonization, quench hardening layer, surface coating, steel, non-ferrous metals and tiny and thin parts, etc. Optional knoop pressure head to the measurement of tiny, thin shape of the specimen and cementation coating specimen microhardness and glass, ceramics, agate, brittle and hard material such as synthetic gems.
Technical parameters:
1. Product model: HMAS-D5, HMAS-D10, HMAS-D20, HMAS-D30, HMAS-D50
2. Six gears force (Kgf):
( HMAS-D5): 0.2、0.3、0.5、1、3、5, ( HMAS-D10) :3、5, 0.3、0.5、1、3、5、10,
( HMAS-D30):1、3、5、10、20、30, ( HMAS-D50):1、5、10、20、30、50
3. Eight gears force (Kgf):
(HMAS-D5):0.2、0.3、0.5、1、2、3、4、5, ( HMAS-D10):0.3、0.5、1、2、3、4、5、10
( HMAS-D20):2、3、5、8、10、12、15、20, (HMAS-D30):2、5、8、10、12、15、20、30
( HMAS-D50):2、5、8、10、15、20、30、50
4. Test force loading: fully automatic (loading/retaining/unloading)
5. Test force load speed: 0.2mm/s
6. Meet the standard (accuracy): GB/T4340.2 national standard, JJG151 verification rules
7. Micrometer eyepiece ratio: 10X (mechanical eyepiece)
8. Measurement and analysis system: HMAS-D measurement and analysis system
9. Micrometer eyepiece movement: 0.4 pitch screw
10. Measurement data acquisition mode: Host manual collection, computer automatic collection
11. Measurement data calculation method: Automatic computer calculation and automatic computer analysis
12. objective magnification: 10X (observation), 20X(measurement), 10X (observation, measurement)
13. Total magnification: 100X (observation), 200X (measurement), 100X (observation, measurement)
14. Measuring length of indentation: mechanical 0.0-670μm, computer 0.0-800μm
15. Tower control mode: manual control
16. Hardness value conversion range HRC: 20-70HR
17. Printer: no computer, computer printout
18. Test storage number: Host no, computer report output storage
19. Hardness theory measurement range: MAX hardness value 6000, mini 0.001
20. Fuselage craft: Casting body (aluminium 10-14mm)
21. Test force reading: rotation twist change, automatic reading
22. Test time: 0-99s (one unit per second)
23. Light source brightness adjustment: 0~100% adjustable, step 5%
24.Hardness value display range: 0.001-9999.9HV
25.Hardness value display mode: computer screen, computer image analysis and measurement
26. Minimum test unit: Host 0.5μm, computer 0.0125μm
27.Detection accuracy: mechanical 0.1μm, computer 0.01μm
28. Max test height: 220 mm
29. Indenter center to the wall distance: 130mm (from the center)
30.Dimensions: 680 (h) × 216 (w) × 565 (d) mm
31. Power: AC220V/50Hz |