MICROCRE · RESEARCH SCIENCE
纤维复合材料与层合结构
研究目标
以铺层方向、界面和缺陷为结构骨架,连接局部应变、整体载荷和失效位置,保留各向异性解释。
研究问题
被测响应属于纤维方向、横向还是层间行为?
切割与夹持是否诱发了原本不存在的分层?
局部应变集中是否与已识别缺陷或铺层转折对应?
组织与性能的关系
纤维方向和层序决定有效响应,均匀各向同性假设须经过论证。
局部缺陷与整体性能的关联需要位置化图像和独立力学证据。
DIC可提供位移场,但精度依赖标定、散斑、相关窗口和出平面运动。
适用边界
普通万能机或显微系统不自动具备DIC或专用层间断裂能力。
单张界面图不足以证明界面强度。
关联仪器、方法与研究依据
论文关联表示方法或研究对象相关,不表示论文采用了本型号仪器。
A Critical Evaluation of Indentation Techniques for Measuring Fracture Toughness: I, Direct Crack Measurements →Ultraviolet digital image correlation (UV-DIC) for high temperature applications →Fracture Toughness Determinations by Indentation →A novel approach for extending autocollimator calibration from plane to spatial angles →Infrared Optical Properties of Materials →Evaluation of measurement data — Guide to the expression of uncertainty in measurement →Evaluation of measurement data — Guide to the expression of uncertainty in measurement. Amendment 1: Nonlinearity in measurement models →Evaluation of measurement data — Supplement 1 to the GUM — Propagation of distributions using a Monte Carlo method →Guide to the expression of uncertainty in measurement — Part 6: Developing and using measurement models →Elastic/Plastic Indentation Damage in Ceramics: The Median/Radial Crack System →Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results →Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review →Traceability Calibration, & Measurement Uncertainty Issues Regarding Coordinate Measuring Machines and Other Complex Instruments →Nanoindentation of B4C-HfB2 particulate ceramic composite doped with Cr–B compounds →Strategies for Transmission Electron Microscopy Specimen Preparation of Polymer Composites →Comparison of Bulk and Micro Sampling Techniques for the Elemental Analysis of SRM 610 and 612 →High-Temperature Mechanical Characterization of CeO2 as a Ceramic Surrogate Fuel Based on FIB and Nanoindentation →Thermally Activated Deformation Mechanisms in MgO Investigated via High Temperature Scanning Indentation →Determination of displacements using an improved digital correlation method →Certification of Standard Reference Material® 2246a Relative Intensity Correction Standard for Raman Spectroscopy: 830 nm Excitation →NIST Surface Roughness and Step Height Calibrations: Measurement Conditions and Sources of Uncertainty →Measurement of high temperature full-field strain up to 2000 °C using digital image correlation →Uncovering dominant mechanisms of nano-mechanical properties of AlTaO4 ceramics from structural characteristics →ASTM Technical Committee Guidance — DIC 测量的报告要求 →NPL Good Practice Guide — DIC 散斑制备与质量评价 →Digital image correlation using Newton-Raphson method of partial differential correction →Applications of digital-image-correlation techniques to experimental mechanics →Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review — Extended reading 31 →Digital imaging techniques in experimental stress analysis →Image Correlation for Shape, Motion and Deformation Measurements →