MICROCRE · RESEARCH SCIENCE
金属增材制造材料
研究目标
将构建方向、平台位置和后处理作为材料状态的一部分,以见证样和实际局部的差异组织验证。
研究问题
方向效应是否与批次、几何或表面状态混杂?
缺陷形貌是否受取样方向和制样方法影响?
见证试样能否代表复杂零件的局部热历史和尺寸?
组织与性能的关系
构建和后处理共同影响组织,方向化取样是解释材料响应的重要输入。
表面及内部缺陷可影响不同力学模式,二维截面不能完整替代三维缺陷证据。
试样尺寸与几何改变测试边界,方向比值只适用于已匹配条件。
适用边界
不提供未经验证的通用成形参数或能量密度配方。
单批见证件结果不能自动用于全部实际零件资格认定。
关联仪器、方法与研究依据
金属增材:构建方向—缺陷—性能 →孔系尺寸与同轴基准链 →自由曲面:配准、法向偏差与采样覆盖 →薄壁件:厚度、接触变形与内腔 →疲劳研究:应力比、循环与未断样 →拉伸性能:从尺寸到应力—应变与断口 →
论文关联表示方法或研究对象相关,不表示论文采用了本型号仪器。
Ultraviolet digital image correlation (UV-DIC) for high temperature applications →Microstructure Analysis for Additive Manufacturing: A Review of Existing Standards →Size-affected single-slip behavior of pure nickel microcrystals →Investigation of complementary use of optical metrology and x-ray computed tomography for surface finish in laser powder bed fusion additive manufacturing →Temperature dependence of the indentation size effect →A novel approach for extending autocollimator calibration from plane to spatial angles →Size dependence of mechanical properties of gold at the micron scale in the absence of strain gradients →Infrared Optical Properties of Materials →Evaluation of measurement data — Guide to the expression of uncertainty in measurement →Evaluation of measurement data — Guide to the expression of uncertainty in measurement. Amendment 1: Nonlinearity in measurement models →Evaluation of measurement data — Supplement 1 to the GUM — Propagation of distributions using a Monte Carlo method →Guide to the expression of uncertainty in measurement — Part 6: Developing and using measurement models →Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results →Indentation size effects in crystalline materials: A law for strain gradient plasticity →Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review →Traceability Calibration, & Measurement Uncertainty Issues Regarding Coordinate Measuring Machines and Other Complex Instruments →Fiji: an open-source platform for biological-image analysis →NIH Image to ImageJ: 25 years of image analysis →Comparison of Bulk and Micro Sampling Techniques for the Elemental Analysis of SRM 610 and 612 →Determination of displacements using an improved digital correlation method →Sample dimensions influence strength and crystal plasticity →Certification of Standard Reference Material® 2246a Relative Intensity Correction Standard for Raman Spectroscopy: 830 nm Excitation →NIST Surface Roughness and Step Height Calibrations: Measurement Conditions and Sources of Uncertainty →Measurement of high temperature full-field strain up to 2000 °C using digital image correlation →Mechanical Metallurgy on Columbia Gas X100 Experimental Pipe →ASTM Technical Committee Guidance — DIC 测量的报告要求 →EURAMET Calibration Guide — 硬度计校准与不确定度评定 →NPL Good Practice Guide — DIC 散斑制备与质量评价 →NPL Good Practice Guide — 不确定度预算的编制 →Digital image correlation using Newton-Raphson method of partial differential correction →Applications of digital-image-correlation techniques to experimental mechanics →Evaluation of measurement data — Guide to the expression of uncertainty in measurement (GUM) →Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review — Extended reading 31 →Digital imaging techniques in experimental stress analysis →Image Correlation for Shape, Motion and Deformation Measurements →