SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
CASES

Image drift and focus stability: worked example

Worked example · not customer test evidence

Objective

Show how Image drift and focus stability is obtained under high vacuum 1e-4 Pa and where the error comes from.

Material

40Cr alloy structural steel (assumed grade and condition)

Context

Used for internal training and plan review; inputs are assumed and do not represent a customer product or acceptance decision.

Example data

Item

Translation pending review.

测得量

Value

20.64

Unit

1

Item

Translation pending review.

修正量

Value

0.413

Unit

1

Item

Translation pending review.

重复次数

Value

3

Unit

1

Calculation steps

Equation

x̄ = (x₁ + x₂ + x₃)/3

Substitution

(20.64 + 21.47 + 21.05)/3

Result

21.053

Unit

1

Interpretation

The result compares positions or processes within one batch; it is not a stand-alone acceptance decision.

Limitations

Equipment bias and environmental gradients are excluded

Too few replicates to estimate process capability

Workflow & steps

01

Fix the purpose and magnification

Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

02

Prepare and clean the surface

Prepare specimens or measurement points for the material and purpose: select the objective by magnification and working distance, calibrate the scale and white balance, avoid clipping, and compare quantitatively under identical illumination and thresholds.

03

Calibrate scale and illumination

Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

04

Capture representative images

Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

05

Segment and measure with thresholds

Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

06

Review statistics and report

Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

Related instruments & resources

Links support navigation and do not establish a model’s performance or standards compliance.

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.